CVE-2025-31930: A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter...

8.8 CVSS

Description

A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child...

Classification

CVE ID: CVE-2025-31930

CVSS Base Severity: HIGH

CVSS Base Score: 8.8

CVSS Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Problem Types

CWE-1188: Initialization of a Resource with an Insecure Default

Affected Products

Vendor: Siemens

Product: IEC 1Ph 7.4kW Child socket, IEC 1Ph 7.4kW Child socket/ shutter, IEC 1Ph 7.4kW Parent cable 7m, IEC 1Ph 7.4kW Parent cable 7m incl. SIM, IEC 1Ph 7.4kW Parent socket, IEC 1Ph 7.4kW Parent socket incl. SIM, IEC 1Ph 7.4kW Parent socket/ shutter, IEC 1Ph 7.4kW Parent socket/ shutter SIM, IEC 3Ph 22kW Child cable 7m, IEC 3Ph 22kW Child socket, IEC 3Ph 22kW Child socket/ shutter, IEC 3Ph 22kW Parent cable 7m, IEC 3Ph 22kW Parent cable 7m incl. SIM, IEC 3Ph 22kW Parent socket, IEC 3Ph 22kW Parent socket incl. SIM, IEC 3Ph 22kW Parent socket/ shutter, IEC 3Ph 22kW Parent socket/ shutter SIM, IEC ERK 3Ph 22 kW Child cable 7m, IEC ERK 3Ph 22 kW Child socket, IEC ERK 3Ph 22 kW Parent socket, IEC ERK 3Ph 22 kW Parent socket incl. SI, UL Commercial Cellular 48A NTEP, UL Commercial Child 40A w/ 15118 HW, UL Commercial Child 48A BA Compliant, UL Commercial Child 48A w/ 15118 HW, UL Commercial Parent 40A with Simcard, UL Commercial Parent 48A (USPS), UL Commercial Parent 48A BA Compliant, UL Commercial Parent 48A with Simcard BA, UL Commercial Parent 48A, 15118, 25ft, UL Commercial Parent 48A,15118 25ft Sim, VersiCharge Blue™ 80A AC Cellular

Exploit Prediction Scoring System (EPSS)

EPSS Score: 0.02% (probability of being exploited)

EPSS Percentile: 4.54% (scored less or equal to compared to others)

EPSS Date: 2025-06-11 (when was this score calculated)

References

https://nvd.nist.gov/vuln/detail/CVE-2025-31930
https://cert-portal.siemens.com/productcert/html/ssa-556937.html