CyberAlerts is shutting down on June 30th, 2025. Thank you for your support!

CVE-2024-41793: A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices provides an endpoint...

8.6 CVSS

Description

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices provides an endpoint that allows to enable the ssh service without authentication. This could allow an unauthenticated remote attacker to enable remote access to the device via ssh.

Classification

CVE ID: CVE-2024-41793

CVSS Base Severity: HIGH

CVSS Base Score: 8.6

CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N

Problem Types

CWE-306: Missing Authentication for Critical Function

Affected Products

Vendor: Siemens

Product: SENTRON 7KT PAC1260 Data Manager

Exploit Prediction Scoring System (EPSS)

EPSS Score: 0.05% (probability of being exploited)

EPSS Percentile: 14.09% (scored less or equal to compared to others)

EPSS Date: 2025-05-07 (when was this score calculated)

References

https://nvd.nist.gov/vuln/detail/CVE-2024-41793
https://cert-portal.siemens.com/productcert/html/ssa-187636.html

Timeline